Measurement modes
Imaging
![icon_Screenshot Q six specifications icon_Screenshot](https://www.sensofar.com/wp-content/uploads/2015/06/part2ScreenShot.png)
Screenshot
![icon_UnrolledFOV Q six specifications icon_UnrolledFOV](https://www.sensofar.com/wp-content/uploads/2015/06/Qsix2SpecsUnrolledFOV.png)
Unrolled FOV
![icon_UnrolledSection Q six specifications icon_UnrolledSection](https://www.sensofar.com/wp-content/uploads/2015/06/QsixSpecsUnrolled.png)
Unrolled section
3D Modes
![icon_SurfaceTopography icon_SurfaceTopography](https://www.sensofar.com/wp-content/uploads/2015/06/QsixSpecspart2SurfaceTop.png)
Surface topography
![icon_SurfaceRoughness icon_SurfaceRoughness](https://www.sensofar.com/wp-content/uploads/2015/06/QsixSpecspart2SurfaceRouch.png)
Surface roughness
![icon_CoatingThickness icon_CoatingThickness](https://www.sensofar.com/wp-content/uploads/2015/06/QsixPart2Thickness.png)
Coating thickness
Inspection capabilities
![iconProduct_Qsix_Outer](https://www.sensofar.com/wp-content/uploads/2015/06/qsix_sp_outer.png)
Outer surface
![iconProduct_Qsix_Inner](https://www.sensofar.com/wp-content/uploads/2015/06/qsix_sp_inner.png)
Inner surface
![iconProduct_Qsix_Sidewalls](https://www.sensofar.com/wp-content/uploads/2015/06/qsix_sp_sidewalls.png)
Sidewalls
Measurable stent
Material | Metal (Stainless Steel, CoCr) and Nitinol |
OD | 1 – 15 mm |
Length | Up to 100mm (XL stage option 250mm) |
Light sources
![icon_GreenLight icon_GreenLight](https://www.sensofar.com/wp-content/uploads/2015/06/QsixSpecsPart5Img11-55x62.png)
530nm
![icon_WhiteLight icon_WhiteLight](https://www.sensofar.com/wp-content/uploads/2015/06/QsixSpecsPart5Img2-55x62.png)
550nm
Dimensions
![photoProduct_QsixDimensionsSide Q six specifications_DimensionsSide](https://www.sensofar.com/wp-content/uploads/2015/06/qsix_sp_dimensions1.png)
![photoProduct_QsixDimensionsFront Q six specifications_DimensionsFront](https://www.sensofar.com/wp-content/uploads/2015/06/qsix_sp_dimensions2.png)
Sensorhead & Controller
Objectives performance
MAG | 2.5X | 5X | 10X | 20X |
Numerical Aperture | 0.08 | 0.15 | 0.20 | 0.45 |
Working Distance (mm) | 8.80 | 23.50 | 37.00 | 4.50 |
Horizontal FOV (mm) | 7.20 | 3.60 | 1.80 | 0.90 |
Spatial sampling (µm)[1] | 3.52 | 1.76 | 0.88 | 0.44 |
Optical resolution (µm)[2] | 1.95 | 0.97 | 0.73 | 0.32 |
Acquisition time (mm2/s) | 20 | 5 | 1.25 | 0.31 |
1 Pixel size on the imaged surface. 2 L&S: Line and Space, half of the diffraction limit according to the Rayleigh criterion. Values for blue LED.
MAG | 10XDI | 20XDI | 50XDI |
Numerical Aperture | 0.30 | 0.40 | 0.55 |
Working Distance (mm) | 7.40 | 4.70 | 3.40 |
Horizontal FOV (mm) | 1.80 | 0.90 | 0.36 |
Spatial sampling (µm)[1] | 0.88 | 0.44 | 0.18 |
Optical resolution (µm)[2] | 0.48 | 0.36 | 0.26 |
Vertical resolution (nm)[3] | 1 | 1 | 1 |
1 Pixel size on the imaged surface. 2 L&S: Line and Space, half of the diffraction limit according to the Rayleigh criterion. Values for blue LED.
3 Vibration isolation table is required.
Computer & Operating System
![photoProduct_Sneox090ComputerDimensions photoProduct_Sneox090ComputerDimensions](https://www.sensofar.com/wp-content/uploads/2019/01/photoproduct_sneox090computerdimensions-326x265.png)
Computer | HP Z220 SFF, HP display 2560×1440 pixels |
Operating System | Windows 10, 64 bits |
Data management
![photoProduct_QsixDataManagementChart Q six specifications Data Management Chart](https://www.sensofar.com/wp-content/uploads/2015/06/qsixSpecsPart8.png)
Depending on the intended use, the Q six can be operated in three different environments: Development, Quality Assurance (QA) and Production. Each environment has its own databases.
Data is organized in three different categories:
1 System Databases containing User data and System configuration files
2 Stent Inspection Databases containing Stent Model data, Defect libraries and Acquisition, Analysis and Report recipes
3 Inspection Results
![icon_Books icon_Books](https://www.sensofar.com/wp-content/uploads/2015/06/QsixSpecsPart9.png)
Sensofar Medical can provide specialized support to QA/RA departments in qualification and validation processes. A complete validation package for the Q six is available as an option.